Protable ICU CCU 6-parameter Patient Monitor Medical Monitor Health Care USA

$ 221.23

Availability: 100 in stock
  • Country/Region of Manufacture: China
  • Item must be returned within: 30 Days
  • Feature 3: Portable Patient Monitor
  • Warranty: 3 years
  • MPN: Does not apply
  • Express shipping: Yes
  • optional: Printer,ETCO2 modul,wifi
  • Alarm Type: Audible & visual alarm
  • All returns accepted: Returns Accepted
  • Multi-language: English, Spanish, Turkish
  • Return shipping will be paid by: Seller
  • EAN: Does Not Apply
  • Refund will be given as: Money back or replacement (buyer's choice)
  • Feature 1: 12" TFT display
  • Model: RPM-9000A
  • Feature 2: 6-Parameter LCD ICU
  • Herstellernummer: Does not Apply
  • Battery: 4 hours of working time
  • Display: 12" TFT display
  • Restocking Fee: No
  • Standard configuration: ECG, NIBP, SPO2, TEMP, RESP, PR, Rechargeable Lithium battery
  • Certifications: FDA CE
  • Brand: Unbranded
  • Support: support use in NICU, ICU, OR, CCU or normal patient room
  • Condition: New
  • Monitor Parameters: Blood Pressure - NIBP

    Description

    Details
    Description:
    Model: RPM-9000A
    Features:
    Ergonomic design, portable, convenient for use
    12" TFT display, configurable up to 8 waveforms, enables maximum data visibility for the most critical parameters
    Unique digital SPO2 technology can work accurate during motion and low perfusion
    Anti AC & high-frequency electrosurgical & defibrillator’s interference
    Rich screen layout, standard, large font, trend graph, OxyCRG, ECG full lead and others
    Strong data storage: 720 hours trends, 10000 group NIBP, 1024 alarms events
    ST analysis, arrhythmia analysis, pacemaker analysis, drug analysis and calculation
    Audible & visual alarm available, adjustable
    Patient information management function
    Powerful software function to support use in NICU, ICU, OR, CCU or normal patient room
    Optional software upgrading based on USB
    Wired/wireless networking with central monitoring system, up to 64 beds in one group
    Built-in 3 trace thermal recorder for printing real-time and historical data
    Multi-language i.e. English, Spanish, Turkish.
    Super long life rechargeable Lithium battery upto 4 hours of working time
    Suitable for adult, pediatrics and neonate patients
    Standard configuration:
    ECG, NIBP, SPO2, TEMP, RESP, PR, Rechargeable Lithium battery
    Optional:
    Dual TEMP
    Dual IBP
    ETCO2 (side stream)
    Thermal recorder
    Wall mount
    Trolley
    Specification:
    ECG
    Full lead: I, II, III, AVL, AVR, AVF and V
    Gain: 5mm/mV, 10mm/mV, 15mm/mV, 20mm/mV and 25mm/mV
    Scanning speed: Changeable with three grades of 12.5mm/s, 25mm/s and 50mm/s
    Band width: 0.05Hz-100Hz(3dB)
    Heart rate:
    Scope: 15 times/minute to 300 times/minutes
    Accuracy:  ±1 time/minute
    Variation of heart beat LORENZE drawing: Analysis on heart beat data for the current 5 minutes with histogram during RR period.
    Arrhythmia: Twenty kinds of common abnormal ECG can be analyzed, with ECG data of 1000 times of arrhythmia kept and with 10 seconds kept for each time.
    Accuracy: Error rate < 20%
    Undetected rate < 20%
    ST section
    Scope:     ±0.8mV
    Precision :  < ±0.05mV
    SpO2
    Detection scope:   0%-100%
    Accuracy         ±1%     90%-100%
    ±2%      70%-89%
    NIBP
    Theory Electric oscillator
    Cuff gassing time   less than 15 seconds
    First-time gassing pressure: dynamic state 24kPa(180 mmHg)
    Manual selection: 9.3kPa(70 mmHg),13.3kPa(100 mmHg),16.0kPa(120 mmHg)
    18.6kPa(140 mmHg),20.0kPa(150 mmHg),21.3kPa(160 mmHg),
    Automatic detection period: 1 minute to 240 minutes
    Stop size:1 min(1 min -10min), 5min(10 min -30min), 10min(30 m
    in -90min) and 30min(90 min -240min)
    Detection scope:
    Systolic blood pressure:   4kPa -34kPa(30mmHg -255mmHg)
    Diastolic pressure             2kPa -29.3kPa(15mmHg -220mmHg)
    Mean pressure               2.7kPa~31.3kPa       (20mmHg~235mmHg)
    Detection accuracy
    Static pressure: ±3mmHg
    Pulse rate:  ±2%
    Resp
    Chest impedance method or concentration of carbon dioxide at end of respiration
    Scope of chest impedance method     0 time/minute – 100 minutes/minute
    Precision of chest impedance method  time/minute
    Detection scope of carbon oxygen at end of respiration 3mmHg-75mmHg; 0.4%vol-9.9%vol
    Detection scope of respiration rate: 2 times/minute ->60 times/minute(including baby)
    Detection precision of respiration rate: ±1 time/minute
    Temp
    Single/double path
    Type:    Vascular/surface temperature
    Scope:    20℃~50℃
    Accuracy:  ±0.2℃
    Invasive blood pressure (optional)
    Single/double path
    Type: direct and continuous detection
    Scope: -6.67kPa(-50mmHg)—46.67kPa(350mmHg)
    Precision: below 13.33kPa(100mmHg) ±0.27kPa(2mmHg)  13.33k
    Pa(100mmHg) above ±2%
    Frequency response:DC-12Hz
    Input resistance: not less than 500kΩ
    Sensitivity of sensor: 5μV/V/mmHg
    Motivation voltage:5V (DC)
    Accuracy of sensor: ±2%Isolation voltage: 4 kV
    Packing List:
    Iitem
    NO.
    Content
    Qty
    Remark
    Standard Configuration
    1
    Main Unit
    1
    2
    Power cable
    1
    3
    ECG Cable
    1
    Integrated
    4
    NIBP Cuff
    1
    Adult
    5
    External NIBP Hose
    1
    6
    SPO2 Probe
    1
    7
    Temperature Probe
    1
    8
    Disposable Electrodes
    1
    9
    Packing List
    1
    10
    Grounding wire
    1
    11
    Operator's Manual
    1
    12
    13
    14
    15
    Optional
    1
    IBP kit
    2
    EtCO2 Set
    3
    Built-in Recorder
    4
    IBP kit
    5
    PAYMENT
    1.We accept payment by
    PayPal
    . PayPal enables you to make payment
    quickly and securely online.
    2.We accept payment via PayPal.Please pay the money within 5
    days
    after the auction ended. 3.
    Please offer home or mobile phone when the item's Value exceeds
    100 (USD, EUR, AUD, GBP)  so that we can make sure you get the
    item
    safely.
    FDA Disclaimer
    The following FDA Disclaimer is required for all eBay listing i
    n
    Healthcare category and is included for REFERENCE:
    The saleof this item may be subject to regulation by the U.S. Food andDrug Administration and state and local regulatory agencies.Ifso, do not bid on this item unless you are an authorized purchaser. If the item is subject to FDA regulation, We will verify your status as an authorized purchaser of this item before shipping of the item.(The seller’s name: Jenny Liu City: Beijing State: Beijing Country: China Telephone number: 86-18789632541)
    The Fingertip Pulse-Oximeter is registered on the Australian Register of Therapeutic Goods (ARTG) with the code 136606, and certified by FDA of United States (Premarket Submission Number (510K): K073454 Listing Number: D045684, K082641 Listing Number: D064765, K090671 Listing Number: D078664); and CE Approved, TUV of Europe (Cert.No. : G1 10 02 50972 013). You can consult with the FDA's Center for Devices and Radiological Health.
    This item has been cleaned and treated according to the manufacturer's instructions.
    SHIPPING
    All items will be shipped  within 2 business day
    .More than 200$,express ship via DHL/UPS/EMS,
    It takes approximately 5-7 days(USA ,CA,AU,UK).other country 7-12 days (European, South America Africa,etc.).
    Notes:
    We will NOT be responsible for any delay during delivery including but not limited to customs postage checking, strike, force majeure etc
    .
    As a buyer, it is your duty to pay the tax when you make a order from abroad. Our price does not include taxes, VAT, or other hidden charges.
    RETURNS
    Warranty:
    We guarantees new equipment other than accessories to be free fro
    m
    defects in workmanship and materials
    for a period of 24 months ( 24months for spare parts)
    from the date of shipment under normal use and service.Our company's obligation under this warranty is limited to repairing,at our company's option, any part which upon our company's examination proves defective.
    If you receive a defective item which you want to return, please contact us within 2 days from the day you receive the item. All return items must be returned with its original packaging and accessories. If we confirm the damage happened during the shipment, we will bear the shipping cost for return.
    We will refund the money to you when we get the return items.Or replace item for you free of charge.
    If buyer want to return for personal reason. The buyer will be in charge of the shipping cost.
    If you are not satisfied with the product or service, please
    contact me and don't give us negative or natural feedback,We must give you a satisfactory solution.
    We are the manufacturer and distributor of medical equipment for more than 10 years. If you are interested in the distribution work, please feel free to contact us.
    ABOUT US
    We are the manufacturer and distributor of medical equipment
    for
    more than 10 years.
    If
    you are interested in the distribution
    work, please feel free to contact  us.
    We will reply to you within48 hours. Please kindly wait for
    us
    .
    During the duty time ,we can give you a quick respond.If we are out of work ,please kindly be patient and considerable to give us
    a little more time,not just leave the neutral or negative feedback without communication ,thank you for your cooperation !
    We are the manufacturer and distributor of medical equipment for more than 10 years. If you are interested in the distribution
    w
    ork, please feel free to contact us.