Portable Multi-parameter Patient Monitor is adaptable to adult, pediatric and neonatal usage. It can monitor vital signals as ECG, Respiratory Rate, SpO2, NIBP, TEMP and IBP.It integrates parameter measuring modules, display and recorder in one device, featuring in compactness, lightweight and portability. Replaceable built-in battery facilitates transportation of patient.Features:
12" high resolution color TFT LCD display.
6 Standard parameters:ECG, RESP, NIBP, SPO2, TEMP, PR.
Can be arbitrarily set the alarm limit, automatic sound and light alarm.
The back of the machine is designed with a storage box, which can put some accessories,convenient for doctors use.
Drug solubility calculation function, Arrhythmia analysis function.
Built-in lithium battery,AC and DC,can provide long-term monitoring after power failure.
Widely used in the Department of internal medicine, Dental practices (both pediatric and adult), oral surgery centers surgery, operation room,obstetrics and Gynecology, pediatrics, emergency center,ICU,CCU.
Specification:
ECG
Lead Mode:5 Leads ( R, L, F, N, C or RA, LA, LL, RL,V)
Lead selection:I, II, III, avR, avL, avF, V,
Waveform:2 ch
Lead mode:3 Leads ( R, L, F or RA, LA, LL)
Lead selection:I, II, III,
Waveform:1 ch
Gain:´2.5mm/mV, ´5.0mm/mV, ´10mm/mV, ´20mm/mV, auto
HR and Alarm
Range:
Adult:15 ~ 300 bpm
Neo/Ped:15 ~ 350 bpm
Accuracy:± 1% or ± 1bpm,which great
Resolution:1 bpm
Sensitivity:> 200 (uV P-P)
Differential Input Impedance:> 5 MΩ
RESPARATION:
Method:Impedance between R-F(RA-LL)
Differential Input Impedance:>2.5 MΩ
Measuring Impedance Range:0.3~5.0Ω
Base line Impedance Range:0 – 2.5 KΩ
Bandwidth:0.3 ~ 2.5 Hz
Resp. Rate
Measuring and Alarm Range
Adult:0 ~ 120 rpm
Neo/Ped:0 ~ 150 rpm
Resolution:1 rpm
Accuracy:±2 rpm
Apean Alarm:10 ~ 40 S
NIBP
Method:Oscillometric
Mode:Manual, Auto, STAT
Measuring Interval in AUTO Mode
1, 2, 3, 4, 5, 10, 15, 30, 60, 90, 120, 180, 240,480 (Min)
Measuring Period in STAT Mode:5 Min
Pulse Rate Range:40 ~ 240 bpm
Alarm Type:SYS, DIA, MEAN
Measuring and alarm range:
Adult Mode
SYS :40 ~ 270 mmHg
DIA :10 ~ 215 mmHg
MEAN:20 ~ 235 mmHg
Pediatric Mode
SYS:40 ~ 200 mmHg
DIA:10 ~ 150 mmHg
MEAN:20 ~ 165 mmHg
Neonatal Mode
SYS:40 ~ 135 mmHg
DIA:10 ~ 100 mmHg
MEAN:20 ~ 110 mmHg
Overpressure Protection
Adult Mode:297±3 mmHg
Pediatric Mode:240±3 mmHg
Neonatal Mode:147±3 mmHg
SpO2
Measuring Range:0 ~ 100 %
Alarm Range:0 ~ 100 %
Resolution:1 %
Accuracy:
70% ~ 100% ±2 %
0% ~ 69% unspecified
Actualization interval:about 1 Sec.
Alarm Delay:10 Sec.
Pulse Rate
Measuring and Alarm Range:0~254bpm
Resolution:1bpm
Accuracy:±2bpm
I.5TEMP measurement:
Channel:1
Measuring and Alarm Range:0 ~ 50 °C
Resolution:0.1°C
Accuracy:±0.1°C
Actualization interval:about 1 Sec.
Average Time Constant:< 10 Sec.
Package List:
1×Patient Monitor
1×EKG Lead wire
1×NIBP Cuff
1×NIBP Extension Cable
1×SpO2 Sensor
1×Temp Sensor
1×Ground Cable
5×Electrode
2×Fuse
1
×User Manual(CD)
*Payment
1.We accept PayPal only. We will ship out the item after receiving cleared payment.
2.Please make sure you PayPal account is valid prior bidding.
3.Great appreciate for prompt payment. Unpaid item will be filed without receiving payment in 7 days after listing ended.
*Shipping
1.After full payment is received and cleared, we will ship it ASAP .
2.A complete and correct shipping address is essential.
3.Generally, mor than 200$,Expedited shipping !!!
*Return Policy
All items are with 2 Years warranty .
we accept returns, contact us within 60 days from delivery date and we will give you a full refund or exchange.
Only unused, undamaged and original condition item can be qualified for a return.
Buyer is responsible for return shipping fee.
*FDA declaration
The sale of this item may be subject to regulation by the U.S. Food and Drug Administration and state and local regulatory agencies. If so, do not bid on this item unless you are an authorized purchaser. If the item is subject to FDA regulation, I will verify your status as an authorized purchaser of this item before shipping of the item.(
The seller Name: Lily Lee, City: Beijing ,State: Beijing,Country: China Telephone number:15001145569)
This item has been cleaned and treated according to the manufacturer's instructions.
The Fingertip Pulse-Oximeter is registered on the Australian Register of Therapeutic Goods (ARTG) with the code 136606, and certified by FDA of United States (Premarket Submission Number (510K): K073454 Listing Number: D045684, K082641 Listing Number: D064765, K090671 Listing Number: D078664); and CE Approved, TUV of Europe (Cert.No. : G1 10 02 50972 013). You can consult with the FDA's Center for Devices and Radiological Health.
*Contact Us
Any questions, please contact us through eBay message, We will reply within 1 business days (public holidays not included).
Our working time: Monday - Friday 9:00 AM - 5:30PM (Beijing)